Brand Name :Fanke
Model Number :CHX-4800KVA/200KV,400KV,600KV,800KV
Certification :ISO9001
Place of Origin :CHINA
MOQ :One Set
Price :Negotiable
Payment Terms :L/C, T/T
Supply Ability :5 sets / 2months
Delivery Time :45~60 working days
Packaging Details :Export standard wooden case with fumigation free
Test Principle :Variable Frequency Resonant Circuit
Usage :On-site AC Withstand Voltage Test
Design Feature :Highed Voltage Modular Test Reactor, Higher Q Value Output ,Multiple Test Range
Component :V/F Power Source, Excitation Transformer,lighter Modular Test Reactor, And Voltage Divider
Test Frequency :30-300Hz
Duty Cycle :15mints or 60 Mints
Test Accuracy :No Less Than 1.5%
Output Waveform :Good Sine Wave
Special For :On-site Test For UHV GIS , GIL , CT, PT
Test Standard :IEC60060-1:2010;IEC 62271-203:2011 for GIS
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

Variable Frequency Resonant Withstand Voltage Test Set , High Voltage Test Set For UHV Substation or GIS

I. Application :


This series of test system mainly aims at AC voltage withstand test of primary equipment of large capacitor and high voltage and can also satisfy field AC voltage withstand test of sorts of capacitance apparatus. HV test reactors use combined series-parallel patterns which not only meet the requirements of voltage withstand of HV transformer, GIS, SF6 breakers,mutual inductions and bushings but also that of long distance XLPE cables ,with compatibility of extensive tests to be a desired voltage withstand test device for power supply system overhauling and electric power engineer construction units.

The above picture is for variable series resonance test system of 5000KVA/1000KV on test field in Shanxi Jindongnan Substation, testing HV
GIS of 1000KV class UHV line in domestic.

Applicable objects
- Long distance XLPE cables with 110KV,220KV,500KV class
- HV GIS or GIL, HV coupling capacitor,capacitor voltage transformer of no more than 1000KV class
- Assembling capacitor(test frequency pledges in 45—65Hz)

II. Main Components:(4000KVA/1000KV test system for example)

SN Name of Components Type and specification Qty. Each weight Each Dimension
1 Variable frequency power FKVF-200kW/380V 1piece 180kgs 750*700*1000mm
2 Excitation transformer CQSB(J)-200kVA 1piece 1800kgs 650*650*800mm
3 HV resonant test reactor CHX(kf)-800kVA/200kV 5pieces 2800kgs D1200*H1250mm
4 Capacitive divider TRF-1000kV/1000pF 1set 550kgs D350*H7600mm
5 Special test accessories 1set

Note:1.Load capacitantor can be optional when small load line is tesing or need analog load to control test frequency .

2.Test reactor can be produced to be 150KV,200KV,250KV,300KV, 350KV, 400KV for each piece rated voltage according to different tested object scope or customer requried. The max. rated current of each HV reactor can be 1~15A optional in this serialized set,

3. HV Damping inductance can be optional for suppressing high frequency harmonics and resisting overvoltage caused from tested object flashover, special in EHV or UHV test set.

III. Test priciple :
Variable Frequency AC Resonant Test System , High Voltage Test Set For UHV Substation Or GIS

VF: Variable Frequency Power Source T : Excitation Transformer
L : Test Reactor Cx: Tested Equipment MOA1: Lightning Arrestor
C1,C2: Voltage divider(C1 is high voltage arm,C2 is low voltage arm )


IV. General Technical Data:

  1. Mode of system test: Series resonant with variable frequency
  2. System model : CHX-4000KVA/200KV,400KV,600KV, 800KV,1000KV
  3. Input power supply : 380±10%(three-phase),50Hz/60Hz
  4. Number of HV test reactor: 4pieces
  5. Rated output capacity: 4000kVA
  6. Rated output Voltage: 200KV,400KV,600KV,800KV,1000KV
  7. Max Test voltage : no more than 200KV,400KV,600KV,800KV,1000KV
  8. Rated output current: 4A /single piece or in series;16A or 20A in parallal
  9. Reg. Freq range : 20Hz-300Hz
  10. Output Resonance voltage waveform: sine wave
  11. THD of output waveform: ≤1%
  12. Insulation level: Under 1.1 times and keeping 1min, normal
  13. Duty cycle : 60mints optional on under rated current working condition ;
  14. Quality factor of test set itself: Q≥60
  15. Temperature rise: Less than 65K under rated current working withn duty cycle;
  16. Noise level: No more than 70B
  17. Reactor Structure: oil immersed type, epoxy tube cylinder type;


V. Technical Feature and advantage

  • Modular design, being able for series-parallel connection of reactors,wide range of application.
  • Operating frequency range:20-300Hz
  • High quality factor value:Q ≥ 100(when f=20Hz) large thermal capacity, low temperature rise, long
  • continuous of performance period
  • Convenient for field test for the size and weight smaller than conventional test transformers.
  • The output voltage waveform is sine wave, the waveform deviation factor ≤ 1%
  • This device can be furnished with special test vehicle and container together
  • PD free design optional.

VI. Main Measuring and control software panel as following :


Variable Frequency AC Resonant Test System , High Voltage Test Set For UHV Substation Or GIS


VII.Accessories

  • Accessory box for storage accessoires
  • Input cables of power source
  • Output cables of power source
  • Output cables of exciting transformer
  • System grounding cables
  • Parallel cables of the reactor
  • HV measuring cables ( the signal output cables of voltage divider )
  • HV output cables(reactor to divide,divider to test object)
  • Supporting base for divider
  • Corona ring for test reactor and divider
  • A final test report, a quality Certificate ,a user manual and a packing list are offered .


VIII. Other Typical Model

1 For 123KV ~300KV class GIS on-site AC hipot test

Model Rated voltage Rated output current Rated output capacity

Application

(From 45Hz starting)

CHX-400KVA/200KV,400KV 200KV*2 2A@200KV 400KVA For 123KV and below class GIS
1A@400KV For 300KV and below class GIS
CHX-800KVA/200KV,400KV 200KV*2 4A@200KV 800KVA For 123KV and below class GIS
2A@400KV For 300KV and below class GIS
CHX-1000KVA/200KV,400KV 200KV*2 5A@200KV 1000KVA For 123KV and below class GIS
2.5A@400KV For 300KV and below class GIS
CHX-2000KVA/200KV,400KV 200KV*2 10A@200KV 2000KVA For 123KV and below class GIS
5A@400KV For 300KV and below class GIS
Special requirement can be made by order

2 For 145KV ~362KV class GIS on-site AC hipot test

Model Rated voltage Rated output current Rated output capacity

Application

(From 45Hz starting)

CHX-500KVA/250KV,500KV 250KV*2 2A@250KV 500KVA For 145KV and below class GIS
1A@500KV For 362KV and below class GIS
CHX-1000KVA/250KV,500KV 250KV*2 4A@250KV 1000KVA For 145KV and below class GIS
2A@500KV For 362KV and below class GIS
CHX-2000KVA/250KV,500KV 250KV*2 8A@250KV 2000KVA For 145KV and below class GIS
4A@500KV For 362KV and below class GIS
CHX-3000KVA/250KV,500KV 250KV*2 12A@250KV 3000KVA For 145KV and below class GIS
6A@500KV For 362KV and below class GIS
Special requirement can be made by order


3 For 170KV ~550KV class GIS on-site AC hipot test

Model Rated voltage Rated output current Rated output capacity

Application

(From 45Hz starting)

CHX-1200KVA/300KV,600KV 300KV*2 4A@300KV 1200KVA For 170KV and below class GIS
2A@600KV For 550KV and below class GIS
CHX-1800KVA/300KV,600KV 300KV*2 6A@300KV 1800KVA For 170KV and below class GIS
3A@600KV For 550KV and below class GIS
CHX-2400KVA/300KV,600KV 300KV*2 8A@300KV 2400KVA For 170KV and below class GIS
4A@600KV For 550KV and below class GIS
CHX-3600KVA/300KV,600KV 300KV*2 12A@300KV 3600KVA For 170KV and below class GIS
6A@600KV For 550KV and below class GIS
CHX-4800KVA/300KV,600KV 300KV*2 16A@300KV 4800KVA For 170KV and below class GIS
8A@600KV For 550KV and below class GIS
Special requirement can be made by order


4 For 123KV ~800KV class GIS on-site AC hipot test

Model Rated voltage Rated output current Rated output capacity

Application

(From 45Hz starting)

CHX-2400KVA/200KV×4 800KV 12A@200KV 2400KVA For 123KV and below class GIS
6A@400KV For 300KV and below class GIS
3A@600KV For 550KV and below class GIS
3A@800KV For 800KV and below class GIS
CHX-3600KVA/200KV×4 800KV 13A@200KV 3600KVA For 123KV and below class GIS
9A@400KV For 300KV and below class GIS
4.5A@600KV For 550KV and below class GIS
4.5A@800KV For 800KV and below class GIS
CHX-4800KVA/200KV×4 800KV 24A@200KV 4800KVA For 123KV and below class GIS
12A@400KV For 300KV and below class GIS
6A@600KV For 550KV and below class GIS
6A@800KV For 800KV and below class GIS
Special requirement can be made by order