Insulator Salt Density Tester , Desk Type Salt Density Tester , Digital Display
I. Product Description:
FK-CT1A digital salt density tester is designed to test the equivalent salt deposit density of insulators, with a easy reading of formula. Rotating mouse makes operate easy. Micro-printer in it makes an easy data retention and contrast. Large LCD display makes a clear parameters checking. Built-in high-capacity lithium battery makes field testing convenient.
II. Configuration
SN |
Name |
Unit |
Qty |
1 |
Host machine |
set |
1 |
2 |
Electrode (K=1.0) |
piece |
1 |
3 |
Power line |
piece |
1 |
4 |
Software CD |
piece |
1 |
5 |
RS-232 data line |
piece |
1 |
6 |
Thermal printing paper |
roll |
1 |
7 |
Instruction manual |
copy |
1 |
III. Technical advantage:
- The salt density of the insulator surface is directly displayed with desk-type operation.
- Imported platinum electrode, stable and reliable.
- Wide measurement range. Salt density range of 0.0001 mg/cm²~ 9.9999 mg/cm².
- It is with micro-printer to make record results accurate, true, effective.
- It is with a built-in high capacity rechargeable lithium battery, which is convenient for field use.
- It is with automatic temperature compensation. Solution conductance values automatically compensates to the value at 20 ℃.
- Accurate measurement data, salt density resolution of 0.0001 bit.
- It is with automatic calibration function. Automatic calibration once starting up to improve the measurement accuracy.
- Operate by rotating mouse, easy to learn, easy to use.
- Full range auto-switching can improve the accuracy if a low-salt density.
- Display with backlight function.
- Measure the conductivity and temperature of the solution, etc.
IV. Technical data
1.Range
- Salt Density:0.0001 mg/cm²~ 9.9999 mg/cm²
- Temperature:0℃ ~ 95℃
- Conductivity:0 ~ 100000μs/cm
2.Accuracy
- Salt Density:Resolution of 0.0001 bit,better than±2% at full range
- Temperature:Resolution of 0.1 bit,better than±0.5℃
- Conductivity: Resolution is 1/1000 of full range,better than±0.5%at full range
3.Display
- LCD display.
- Output test data by printer.
- Process on a PC by data cable.
4.Using conditions
- Ambient temperature:0℃ ~ 50℃
- Relative humidity: ≤80%
- Power:AC 220V ±10%
5. Dimension and weight
- Dimension:355 mm×250 mm×140 mm
- Weight:about 2.5 KG